Troubleshooting Guide for Inverter Upgrade Failure【SOLARMAN Business】

Troubleshooting Guide for Inverter Upgrade Failure【SOLARMAN Business】

scene1:Inverter upgrade failed due to a failure in parsing the display result.


Reason for failure:
The timeout setting for the upgrade task is too short, leading to a verification failure because the inverter and other devices have not completed the upgrade operation or the first data transmission after the upgrade has not yet reached the cloud platform.
Solution:
1. First, check if the machine has actually completed the upgrade through its LCD display; if it has, ignore the failure message on the software platform;
2. If the machine has not yet completed the actual upgrade process, please wait for the machine to finish upgrading and for all date logger indicator lights to reset to their normal state. Then, after approximately 3-5 minutes, check if the version information associated with this upgrade has been updated.
3. If the device has not completed the upgrade operation after checking steps 1 and 2, please confirm that the information of the firmware package used for this upgrade in the platform's 'Firmware Management' function is correct, and check if there are any incorrectly associated upgrade judgment fields;
4. If no issues are found after checking steps 1, 2, and 3, please confirm whether the ARM version, DSP version, and other related values of the inverter and other device will change after the firmware update. If these values do not actually change, the cloud platform will be unable to determine that the upgrade was successful.


scene2:Inverter upgrade failed, error: Command sending failed

Reason:
1. Data acquisition devices used by inverters and other devices are offline
2. Poor date logger network quality, unstable communication
Troubleshooting operation:
1. Check if the inverters or data collection devices on the platform are shown as online
2. Check if the indicator lights on the data acquisition device are working normally. Normally, a properly functioning device will have the NET light constantly on or blinking, and the Ready light blinking. If the indicator lights are not in their normal state, please refer to the device manual for network configuration or check the SIM card fee status.
3. If the network to which the data acquisition device is connected has poor communication quality, please try re-plugging the date logger and check the current router network and Ethernet network quality;

scene3:Inverter Upgrade Display Firmware Package Download Failed

The current Data Logger network quality is poor, and communication is unstable.
1. If the network connected to the Data acquisition device has poor communication quality, please try replugging the Data Logger and check the network quality of the current Router network and Ethernet network. 
2. If a large number of connected devices are accessing the network to which the Data acquisition device is connected, Network Channel Congestion may occur. Please try connecting the Data Logger to an alternative network. If no other networks are available on-site, please try restarting the Router to alleviate the congestion. 
3. Please confirm that the router network connected to the current Data Logger has no external network access restrictions.

Scenario 4: Handling Firmware Name Error During Inverter Upgrade Failure

Cause: Poor network quality and unstable communication with the current data logger.
Check the on-site network. Network latency may also cause firmware name errors. If the network is functioning properly, please provide the device SN, screenshots of the error, and other relevant information to contact the platform's after-sales support for verification and resolution.

    • Related Articles

    • LS4G-6-G Data Logger After-Sales Troubleshooting SOP

      Scenario 1: Device Offline in 4G Mode 1. Check Hardware Connections 1.1 Ensure the 4G antenna is installed and securely fastened. 1.2 Open the SIM card slot to make sure the card is inserted in the correct direction with good contact. 2. Check SIM ...
    • Inverter upgrade displays a device interaction failure.【SOLARMAN Smart】

      Data loggers and other devices such as inverters are experiencing transmission interruptions or serial communication anomalies. Please submit a support ticket with your device serial number (SN), screenshots, and other relevant information for ...
    • P1 Meter Reader Troubleshooting FAQ

      Q1: What are the common causes of network configuration failure? A1: Please check the following points: WiFi frequency: Device supports 2.4GHz WiFi. (5GHz is not supported.) WiFi password: Password should be correct. WiFi signal : Signal should be ...
    • Can I customise report templates?【SOLARMAN Business】

      Yes, you can do this on your computer. The navigation path is: Analysis - Reports - Report Templates. We currently support the creation of up to 10 custom report templates per merchant.
    • Firmware Upgrade【SOLARMAN Business APP】